Syntax Control statements can begin in any column. Continuations cannot be
used.
REPT [PCT=n]
CONI n n [n]...[n]
CONO NV=n
COPY n
Definitions If used, REPT must be the only control statement submitted. The
following provides the definition for the parameter you can use with the
REPT control statement.
Parameter Definition
PCT=n Optional and is most accurate for offload
datasets that reside on cartridge media. If
PCT=n is present, the Offload Consolidation
report will print the phrase Consolidation
Candidate next to each dataset version with a
number of blocks in non-scratch status
percentage equal to or less than n. For
example, if PCT=30 is specified and version
7 of an offload dataset has 25% of its
available blocks in use, the dataset will have
Consolidation Candidate listed next to its
report line. The value for blocks available is
based on an estimate of the number of 64K
blocks that will fit on the various cartridge
media. The value for the number of available
blocks in non-scratch status is taken from
data in the BIM-EPIC Catalog. For example:
REPT
REPT PCT=40